(028) 6258 5368pH/ORP/Conductivity buffer solution
Etatron pH, ORP, and conductivity buffer solutions are specialized reference solutions used to test and calibrate pH, ORP/redox, and conductivity meters in industrial water treatment systems. These solutions offer high chemical stability, precise reference values, and diverse standard ranges, and come in chemically resistant polyethylene bottles ideal for laboratory analysis and on-site calibration.
PRODUCT FEATURES
- Highly stable reference values and high accuracy.
- High compatibility with a wide range of pH, ORP, and conductivity meters.
- Chemically stable formulation designed to minimize drift during calibration.
- Chemical-resistant polyethylene packaging to prevent environmental contamination.
- User-friendly design suited for both laboratory and field use.
- Available in multiple volume sizes to support residential, commercial, and industrial water treatment applications.
SPECIFICATIONS
-
pH buffer solution
pH 4 / pH 7 / pH 9
-
ORP buffer solution
475 mV / 650 mV
-
Conductivity buffer solution
1413 µS/cm / 12880 µS/cm
-
Available volume
55 mL / 500 mL
-
Available volume on request
250 mL
-
Container material
Polyethylene
Etatron pH, ORP, and conductivity buffer solutions meet the calibration and accuracy-check requirements of analytical instruments used in water treatment, laboratories, and process industries. Depending on the application, Etatron offers a comprehensive selection of standard reference solutions for pH, ORP, and conductivity meters to ensure accurate, reliable measurements.
1. pH calibration solutions
Etatron standard pH buffer solutions establish accurate calibration points for pH electrodes, enabling instruments to respond precisely to H+ ion concentrations in process water samples. Each specific pH buffer solution, including popular types like pH 4 buffer solution and pH 7 buffer solution (buffer solution pH 7), acts as a reliable reference standard with a defined buffer solution pH range.
The exact formula of the buffer solution and carefully balanced components ensure that the buffer solution ensures that the function of a buffer solution and the core purpose of buffer solution are fully met, accommodating diverse industrial process requirements. These standard pH buffer solutions and general pH buffer solutions are essential for routine verification in water treatment plants and laboratories.
Functions and applications:
- Calibrating pH meters and transmitters.
- Verifying the signal accuracy of pH electrodes.
- Ensuring measurement reliability during continuous industrial operation.
Product specifications:
| pH value | Product code | Volume |
|---|---|---|
| pH 4 | ASZ0000101 | 55 mL |
| pH 7 | ASZ0000201 | 55 mL |
| pH 9 | ASZ0000301 | 55 mL |

2. Conductivity calibration solutions
Etatron conductivity calibration solutions, often called EC or conductivity buffer solutions, are used to check and calibrate conductivity sensors, ensuring accurate measurements of electrical conductivity or Total Dissolved Solids (TDS) in water. These solutions are widely used in RO systems, DI water production, boiler feedwater systems, and various industrial water treatment processes, demonstrating the practical importance of buffer solutions and their diverse applications of buffer solutions in plant operations.
Functions and applications:
- Calibrating conductivity meters and controllers
- Verifying the cell constant of conductivity sensors
- Minimizing measurement errors in industrial process loops
Product specifications:
| Conductivity value | Product code | Volume |
|---|---|---|
| 1413 µS/cm | ASZ0000901 | 500 mL |
| 12880 µS/cm | ASZ0001001 | 500 mL |

3. ORP calibration solutions
Etatron ORP buffer solution and redox buffer solution options are used to verify the response and accuracy of oxidation-reduction potential (ORP) electrodes in water streams. These solutions are essential for maintaining stable ORP monitoring and chemical disinfection control across water treatment systems and swimming pool facilities.
Functions and applications:
- Calibrating ORP/redox meters
- Evaluating the performance of ORP electrodes
- Ensuring accurate control of oxidation-reduction processes
Product specifications:
| ORP value | Product code | Volume |
|---|---|---|
| Rx 475 mV | ASZ00001101 | 55 mL |
| Rx 650 mV | ASZ00001501 | 55 mL |

4. How to use Etatron pH, ORP, and conductivity calibration solutions
To ensure maximum calibration accuracy, follow the manufacturer’s recommended handling and calibration procedures.
Basic steps:
- Rinse the electrode thoroughly with deionized (DI) or distilled water and gently blot dry with a clean, lint-free tissue.
- Pour a small volume of the calibration solution into a separate, clean sample cup.
- Immerse the electrode into the solution and wait for the reading to stabilize.
- Calibrate according to the reference value printed on the product label.
- After calibration, rinse the electrode again with distilled water.
Important handling precautions:
- Never submerge the electrode directly into the primary stock bottle.
- Do not reuse spent calibration solutions.
- Store solutions in a cool, dry place away from direct sunlight.
- Perform scheduled routine calibrations to maintain instrument accuracy.
5. Advantages of Etatron calibration buffer solutions
When evaluating the features of buffer solution formulations, understanding a buffer solution definition, and meeting strict operational requirements for a buffer solution, Etatron calibration solutions are widely trusted by water treatment plants and testing laboratories for their high stability and reliability.
Across all standard types of buffer solution offered, the key uses of buffer solution deliver distinct advantages:
- Long-term value stability under standard storage conditions
- High accuracy for electrode calibration
- Temperature compensation reference tables printed directly on product labels
- Significantly reduces measurement errors during process monitoring
- Compact packaging configuration, easy to store and transport for field service
- High compatibility with a wide range of analytical instruments
Additionally, the product labels include explicit temperature correction tables for 20°C, 25°C, and 30°C to help operators achieve higher calibration precision under changing field operating conditions.
6. Trusted supplier of genuine Etatron calibration solutions
ATS Water Technology is a leading distributor of genuine Etatron pH, ORP, and conductivity buffer solutions in Vietnam, supporting industrial water supply treatment, analytical instrumentation, and chemical dosing systems.
Our distribution portfolio includes a complete line of reference standards, including pH 4, pH 7, and pH 9 buffer solutions; 475 mV and 650 mV ORP solutions; and 1413 µS/cm and 12880 µS/cm conductivity reference solutions, each with transparent technical datasheets and part numbers.
Backed by extensive experience in water treatment instrumentation, ATS Water Technology guarantees authentic products imported directly from Italy, complete with full certificates of origin (CO/CQ) and product documentation.
Our technical support team also helps clients select the exact calibration solution for their specific pH, ORP, or conductivity meters, ensuring measurement precision and long-term operational stability across all water treatment skids.
ATS WATER TECHNOLOGY CO., LTD
- Head office: 54/18 Bui Quang La, An Hoi Tay Ward, HCMC, Vietnam
- Branch office: 77 DHT10B, Dong Hung Thuan Ward, HCMC, Vietnam
- Consultation and support: (028) 6258 5368 – (028) 6291 9568
- Email: info@atswatertechnology.com
- Social media: Facebook | LinkedIn | YouTube
- Quick contact: Zalo Official | Telegram | WhatsApp
How can we help you?
Solution
Technology
Application